HIMOINSA continues to develop advanced engineering solutions for Power Solutions projects, such as the container version of the HGY Series, which is one of the most compact and fully integrated.
The Advanced Compact Version of the HGY Series, in a container configuration (ISO High Cube 40′), focuses on highly critical operating environments, where technical aspects such as robustness, efficiency and advanced acoustic engineering solutions are prioritised. Along with the features it inherits from the Open Skid version, the ISO 40′ container version with CSC Safety Approval has been designed to ensure high levels of accessibility for operation, configurable soundproofing levels, Plug & Play system, and connectivity.
Advanced Acoustic Engineering Solutions
The HGY container version reflects HIMOINSA’s ability to provide acoustic engineering solutions, delivering high-performance technology that exceeds expectations and the most demanding requirements in mission-critical sectors such as Data centres, Healthcare and Industry, where the aim is to reduce noise emissions. For projects with these requirements, the Advanced Compact Version has been specially designed to guarantee the lowest noise levels. HIMOINSA’s hallmark is that it integrates a team specialising in acoustic engineering into its organisational structure, which provides ad hoc solutions from the start of the project and integrates and coordinates each solution with the rest of the engineering teams working on the development to offer a unique solution on the market.

The design of the cooling system directs the airflow in and out to minimise aerodynamic noise and improve acoustic efficiency. The adjustable extraction system allows the flow rate to be adjusted, significantly reducing noise levels. Each unit is calibrated at the factory through acoustic testing, verifying the sound configuration chosen for the rated power and actual load conditions, ensuring stable performance and a controlled sound environment.
Sustainability | SCR system and gas post-treatment
In response to greater environmental demands and increasingly stringent regulatory frameworks, HIMOINSA’s engineering team is considering the incorporation of an SCR (Selective Catalytic Reduction) system, configured and available for projects that require special gas treatment. This system injects a urea solution into the hot gas flow, causing a chemical reaction that converts nitrogen oxides (NOx) into nitrogen and water vapor, compounds that are harmless to the environment.
The SCR system installed in the HGY Series allows real-time monitoring of parameters such as temperature, pressure, and NOx concentration. This connectivity ensures comprehensive process control, reduces the risk of incidents, and extends the service life of components. Thanks to this approach, NOx emissions are kept below 190 mg/Nm³, which is the European standard for medium combustion power plants, positioning the HGY Series in its container version as one of the best sustainable Power Solutions in Europe.

Robustness with high operability | Engineering designed for uninterrupted operation
Integrating the entire system into 40 feet offers a compact engineering solution for the customer: shorter electrical layouts and reduced losses, with CSC Safety Approval for intermodal logistics without adjustments. This concentration of capabilities in a single module sets the container version of the HGY Series apart for its functional density and integration quality, putting more power and control in less space and accelerating the project’s entry into operation.

The container is designed to keep the supply operational during scheduled work, avoiding service interruptions, and ensuring continuity of power in demanding environments. When it comes to safety, every detail counts: weather-resistant stainless steel/galvanised fittings; inspection window to the panel for reading measurements and alarms without having to access the interior; openings, registers and sensitive levels to facilitate inspection and service work; LED service lighting; panic button; interlocked switch on the door; and certified lifeline on the roof for working at height. This set of safety features standardises procedures for all maintenance and commissioning work.
The robustness of the container version of the HGY Series results in excellent, uninterrupted operation, laying out the foundations for achieving the highest level of efficiency.
Efficiency and Adaptability to the environment
The HGY Series Advanced Compact Version is designed to deliver higher performance and excellent stability: electrical quality in accordance with class G3 (ISO 8528-5), consistent starts and clean integration with existing switchgear, reducing risks and commissioning times. Its design prioritises efficiency, with reduced consumption and dynamic adaptability between engine operation and cooling management to maintain performance in all conditions. The Engine Control Unit (ECU) integrates intuitive diagnostic software and remote monitoring, facilitating comprehensive management, and increasing the operational availability of the unit. Sensor-based monitoring of the filtration and level systems reduces the number of incidents and provides traceability for each maintenance action.

In terms of efficiency and consumption, the GY engine is best-in-class, setting the benchmark in the market for its low fuel consumption levels, which have a direct impact on reducing OPEX and CO2 emissions in any project.
The Yanmar GY engine is developed to offer quality, durability, and high performance in the most demanding conditions. These engines integrate common-rail injection systems, as well as an advanced piston head design and comprehensive fluid analysis, which optimise combustion and improve efficiency.
In terms of efficiency and consumption, the GY engine is best-in-class, setting the benchmark in the market for its low fuel consumption levels, which have a direct impact on reducing OPEX and CO2 emissions in any project.
High performance in extreme temperatures
Insulation in critical lines preserves the efficiency of aftertreatment (SCR) and protects sensitive components from extreme temperatures. The remote cooling system is designed to work in extreme environments such as hot climates, providing a high ATB value, while self-regulating according to the temperature and load level at any given moment, minimising auxiliary consumption and maximising the power available to deliver to customer loads.
Operational ease | Guaranteed availability

To reinforce and guarantee availability, the architecture can include N+1 pump redundancy, bypass valves, and partial hot maintenance. The result is predictable and traceable operation, with condition records that facilitate maintenance planning without affecting system performance.
Plug & Play | Immediate commissioning
One of the great advantages of the HGY Advanced Compact Version Series is its easy installation and commissioning by technicians thanks to the Plug & Play system. The commissioning procedure does not require specific training, which speeds up installation. It integrates a copper busbar and internal connectors for the SCR system, which allows the installation to be activated very easily and significantly facilitates wiring and technical service tasks. The motor sensors are integrated into the panel by means of labelled and point-to-point tested harnesses, quick fuel connectors with fittings, and a 3-way valve system for fuel purging in a single movement. This 360º approach to accessibility and maintenance ensures that the HGY Series operates with maximum efficiency and reliability.


Connectivity | Advanced monitoring
Connectivity is total for the end customer of each project. Management can be local or remote, as the modules can be synchronised with other generator sets, and the communications modules allow remote control, integration with other generators sets, and GPS tracking. The system integrates communications redundancy and industrial protocols, with API for DCIM/SCADA and centralised alarm and maintenance management. This connectivity consolidates an intelligent and redundant monitoring model, essential in critical infrastructures where reliability is a non-negotiable factor.

Easy maintenance

Another major advantage is the extended maintenance intervals: up to 500 hours for oil and oil filter changes; up to 10,000 hours for top overhaul changes in COP applications; and up to 30,000 hours for major overhauls in COP applications.
About HIMOINSA Power Solutions Ltd

For further information please visit https://www.himoinsa.co.uk/ or contact cdix@himoinsa.com / tel: 00441270536940